Inicio Tests and packing list Tests

Technical specifications


| Test | Packing list |


Tests


01. Water absorption
02. Resistance to freezing
03. Moisture expansion
04. Crushing strength
05. Absolute dry density
06. Linear thermal expansion
07. Apparent dry density

Construction System Test


Wall testing

ensayo_termico

Heat insulation Test
Click on the image
to enlarge

ensayo_acustico

Sound insulation Test
Click on the image
to enlarge

Heat insulation:


It meets the new CTE
(U<0,41 W/m2·K)


Sound insulation:

It meets the new CTE
(RA> 56,2 dBA)

Tests on the SIERRABLOCK® parts.
Dimensional
Tolerances:

Soluble
salts:

Water
Absorption:

Moisture
Expansion:

Crushing
strength:

Reaction
to Fire:


Resistance
to freezing:


Meets Standard
EN 772-16 : 2001

Meets Standard
EN 772-5 : 2002

Way below the Standard
(<3%)

Meets Standard
UNE 67036 : 1999

Way above the Standard
EN 772-1 : 2002

Classified as
Class A1

Meets Standard UNE
67028:1997 EX
(FROST-PROOF).

ensayo SIERRABLOCK
Wall for exposed façade.
1. SIERRABLOCK® BASE Part
2. Sprayed polyurethane (30 kg/m2)
3. Cavity
4. Large 7cm Lining
5. Plaster


>>Click on the image to enlarge

01. Water absorption. (up>>)


REPORT DETAILS

Number

S-PA-185-0021-09

Date of issue

19/02/2009

thumb_absorcion_agua

Water absorption
Click on the image
to enlarge
Standard: UNE-EN 771-1:2003
Specifications of parts for brickwork manufacture. Part 1: Fired clay parts (Appendix C).

Test Start Date
16/02/2009
Test End Date
19/02/2009
RESULTS OBTAINED


Reference
09025-1
09025-2
09025-3
09025-4
09025-5
09025-6

09025-7

09025-8

09025-9

09025-10

Dry Mass [dmass, u] (g)
12753
12764
12778
12788
12761
12780
12772
12776
12785
12765
Saturated Mass [ma,u] (g)
13132
13153
13161
13080
13062
13049
13098
12987
12963
13093
Water Absorption [Wm] (%)
3%
3%
3%
2%
2%
2%
3%
2%
1%
3%
Number or Parts Tested:10


Mean value

Value Guaranteed by the Manufacturer
Water Absorption [Wm] (%)
2%


The measurement uncertainty (k=2) ) of the individual values is: I = ± 1%
The uncertainty (k=2) for the mean value is: I = ± 1%

02. Resistance to freezing (up>>)


REPORT DETAILS

Number

S-PA-185-0125-08

Date of issue

26/01/2009

heladicidad

Resistance to freezing
Click on the image
to enlarge

Standard: UNE 67028:1997 EX.
Fired clay ceramic bricks. Test for Resistance to Freezing


Test Start Date
15/01/2009
Test End Date
23/01/2009
RESULTS OBTAINED
Defects Observed

Reference
08526-21
08526-22
08526-24
08526-25
08526-26
Flaking
-
-
-
-
-
Chipping (Φ >15mm)
-
-
-
-
-
Breakage
-
-
-
-
-
Fissures
-
-
-
-
-
Number or Parts Tested: 6

Flaking, chipping or breakage in one or more bricks

no
Fissures in two or more bricks
no

Classification of the sample

Frost-proof bricks

03. Moisture expansion (up>>)


REPORT DETAILS

Number

S-PA-185-0125-08

Date of issue

26/01/2009

expansion_humedad

Moisture expansion
Click on the image
to enlarge
Standard: UNE 67036:1999.
Fired clay ceramic products. Test for moisture expansion.

Test Start Date
16/01/2009
Test end date
23/01/2009
RESULTS OBTAINED


Reference
08526-27
08526-28
08526-29
08526-30
08526-31
08526-32
Moisture Expansion (A) (mm/m)
0,01
0,01
0,01
0,01
0,00
0,03
Potential Expansionl (B) (mm/m)
0,00
0,00
0,00
0,00
0,00
0,02
Number of Parts Tested:: 6


Mean value

Manufacturer
Expansión por Humedad (A) (mm/m)
0,01
-
Expansión Potencial (B) (mm/m)
0,00
-
Moisture Expansion(A) (mm/m).
The measurement uncertainty (k=2) of the individual values is: I = ± 0,01 (m/m)
The uncertainty (k=2) for the mean value is: I = ± 0,02 (m/m)
Potential Expansion (B) (mm/m):
The measurement uncertainty (k=2) of the individual values is: I = ± 0,01 (m/m)
The uncertainty (k=2) for the mean value is: I = ± 0,01 (m/m)

04. Crushing strength. (up>>)


DATOS DEL INFORME

Number

S-PA-185-0125-08

Date of issue

26/01/2009

resistencia_compresion

Crushing strength
Click on the image
to enlarge
Standard:UNE-EN 772-1:2002.
Testing methods for parts used in brickwork manufacture, Part1: Determination of the crushing strength.

FTest Start Date
14/01/2009
Test End Date
23/01/2009
RESULTS OBTAINED

Spot facing
Conditioning
Position of the Part in the Testing Machine

Cement Mortar CEM II 52,5

Samples 7 days in water
Stress Perpendicular to the Edges
Number of Parts Tested: 10


Reference
Dimensions (mm)
Superface area (mm2)
Breaking Load (N)
Crushing strength (M/mm2)
StandardisedResistance
[fb] (N/mm2)

length
width
thickness
08526-11
401
119
261
47719
641900
13,5
22,8
08526-12
400
119
260
47600
614600
12,9
21,8
08526-13
401
119
261
47719
391900
8,2
13,9
08526-14
402
119
260
47719
538600
11,3
19,1
08526-15
401
119
260
47838
437900
9,2
15,6
08526-16
401
119
262
47719
451000
9,5
16,1
08526-17
401
119
261
47719
643700
13,5
22,8
08526-18
401
119
261
47719
603600
12,6
21,3
08526-19
401
119
261
47719
468700
9,8
16,6
08526-20
401
119
260
47719
784100
16,4
27,7
Shape correction factor (δ)
1,41

Mean Standardised Resistance [fb] (N/mm2)
19,8
Conditioning factor
1,2

Standard Deviation (σn-1)

2,54

The uncertainty (k=2) for the mean value is: I = ± 1,8 (N/mm2)
The measurement uncertainty (k=2) of the individual values is: I = ± 0,2 (N/mm2)
Coefficient of Variation of the Sample (CV)
21,7%

05. Absolute dry density (up>>)


REPORT DETAILS

Number

S-PA-185-0021-09

Date of issue

19/02/2009
densidad_absoluta_seca
Absolute dry density test
Click on the image
to enlarge
Standard: UNE-EN-772-13:2001. "Methods of testing pieces for masonry work. Part 13: Determination of the absolute dry density and apparent dry density of pieces for masonry work (except natural stone)”. Absolute dry density test.
Test Start Date
16/02/2009
Test End Date
19/02/2009

RESULTS OBTAINED


Reference
09025-1
09025-2
09025-3
09025-4
09025-5
09025-6

09025-7

09025-8

09025-9

09025-10

Dry mass [drym, u] (g)
12753
12764
12778
12788
12761
12780
12772
12776
12785
12765
Net volume [Vn,u] (cm3)
5520
5520
5540
5460
5470
5470
5480
5420
5410
5490
Absolute density [ρn,u] (kg/m3)
2310
2310
2310
2340
2330
2340
2330
2360
2360
2330
Number or Parts Tested:10


Mean value

Value Guaranteed by the Manufacturer
Absolute density [ρn,u] (kg/m3)
2330


The uncertainty (k=2) of individual value measurements is I=± 10(kg/m3)
The uncertainty (k=2) for the average value is: I = ± 20(kg/m3)

06. Linear thermal expansion (up>>)


REPORT DETAILS

Number

S-PA-185-0021-09

Date of issue

13/03/2009

dilatacion_termica_lineal

Linear thermal
expansion test

Click on the image
to enlarge
Standard:UNE-EN ISO -10545-8:1996. "Ceramic tiles. Part 8: Determination of linear thermal expansion"
Test Start Date
11/03/2009
Test End Date
13/03/2009
RESULTS OBTAINED
Test-tube:
Linear thermal expansion coefficient α (25-100ºC)
Sense 1 (longitudinally)
5,0 x 10-6 ºC-1
Sense 2 (transversally)
5,0 x 10-6 ºC-1

07. Apparent dry density (up>>)


REPORT DETAILS

Number

S-PA-185-0021-09

Date of issue

19/02/2009

thumb_densidad_aparente_seca

Apparent dry density test
Click on the image
to enlarge
Standard: UNE-EN 772-13:2001
Methods of testing pieces for masonry work. Part 13: Determination of the absolute dry density and apparent dry density of pieces for masonry work (except natural stone)”.

Test Start Date
16/02/2009
Test End Date
18/02/2009
RESULTS OBTAINED


Reference
09025-1
09025-2
09025-3
09025-4
09025-5
09025-6

09025-7

09025-8

09025-9

09025-10

Dry mass [drym, u] (g)
12753
12764
12778
12788
12761
12780
12772
12776
12785
12765
Gross volume [Vg,u,u] (cm3)
11930
11930
11960
11880
111850
11880
11880
11850
11800
11900
Apparent density [ρg,u] (kg/m3)
1070
1070
1070
1080
1080
1080
1080
1080
1080
1070
Number or Parts Tested:10
Type of pieces: complete pieces


Mean value

Value Guaranteed by the Manufacturer
Apparent density  [ρg,u] (kg/m3)
1080


The uncertainty (k=2) of individual value measurements is: I = ± 10 (kg/m3)
The uncertainty (k=2) for the average value is: I = ± 10 (kg/m3)       

 
Italian - ItalyEspañolEnglishFrench (Fr)